Bowers-group XTD Digital Bore Gauge Manuale Utente

Navigare online o scaricare Manuale Utente per Strumenti di misura Bowers-group XTD Digital Bore Gauge. Bowers Group XTD Digital Bore Gauge User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Digital
Internal Micrometer
Operating Instructions
Electronics
Micromètres
d’Intérieur Digitaux
Manuel d’Utilisation
Digitale
Innenmessschrauben
Bedienungsanleitung
Istruzioni per i Micrometri
per Interni
versione
Micrometros de Interiores
Digitales
Manual de instrucciones
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1

DigitalInternal MicrometerOperating InstructionsElectronicsMicromètresd’Intérieur DigitauxManuel d’UtilisationDigitaleInnenmessschraubenBedienungsanle

Pagina 2

1918RESOLUTION POLARITY RESOLUTION/POLARITÉ AUFLÖSUNG/POLARITÄTRISOLUZIONE ED INVERSIONE DEL CONTEGGIO RESOLUCIÓN/ POLARIDADCHANGING BATTERY CHANGEMEN

Pagina 3

2021IP65 PROTECTION PROTECTION IP65 IP65 - SCHUTZPROTEZIONE IP65 PROTECCION IP-65Please note the IP65 Protection rating forthe instrument contained in

Pagina 4 - < 1 sec

INS: 57-36-3SPECIAL INTERNAL APPLICATIONS APPLICATIONS SPÉCIALESSONDERANFERTIGUNGEN APPLICAZIONI SPECIALI APLICACIONES ESPECIALESMany internal measuri

Pagina 5

OperationFasciaLCD DisplayButton FunctionsThe DisplaySet ModeReference ModeFreeze DisplayPreset ModePreset RecallZero RecallMin Max ModeTolerance Mode

Pagina 6

The gauge should be placed intothe appropriate measuring ringto set or check the calibration.Place the gauge into the bore tobe measured, ensuring tha

Pagina 7 - MODALITA’ PRESET MODO PRESET

76FASCIA AFFICHAGE ANZEIGELCD DISPLAY AFFICHAGE LCDDISPLAY LCD PANTALLA DIGITALLCD-ANZEIGENOMENCLATURA DEL DISPLAY UNIDADBUTTON FUNCTIONS FONTIONS DES

Pagina 8

There are five electronic functionsavailable: SET, REF I, II or III, PRESET,MIN MAX and TOLERANCE.To change between each modePress MODE and Hold.Per p

Pagina 9

1110REFERENCE MODE MODE “REFERENCE” REFERENZ MODUSMODALITÀ RIFERIMENTO MODO REFERENCIAPRESET MODE MODE “PRESET” PRESET MODUSMODALITA’ PRESET MODO PRES

Pagina 10

1312PRESET MODE MODE “PRESET” PRESET MODUSMODALITA’ PRESET MODO PRESETPRESET RECALL RAPPEL DU PRESET AUFRUF PRESET-WERTRICHIAMO DEL VALORE PRESETTATO

Pagina 11

1514ZERO RECALL RAPPEL DU ZERO AUFRUF NULL-WERTRICHIAMO DELLO ZERO PUESTA A CEROMIN MAX MODE MODE MINI/MAXI MIN-/MAX MODUSMODALITA’ MIN MAX MODO MIN M

Pagina 12

1716TOLERANCE MODE MODE “TOLERANCE” TOLERANZMODUSMODALITA’ TOLLERANZE MODO TOLERANCETOLERANCE MODE MODE “TOLERANCE” TOLERANZMODUSMODALITA’ TOLLERANZE

Commenti su questo manuale

Nessun commento